[Equipment]
- Laptop/Desktop, with Tera Term VT (user can download from internet directly)
- EMBUX ICM-3011 series
- Power adapter for ICM-3011 series
- USB to serial port cable
- HDMI/LVDS panel, please check with EMBUX LCD compatible list
[Environment]
- Make sure the DIP switches setting as below:
- Connect COM port(JCOM1) with Laptop/Desktop
- Run Tera Term and
[Procedure]
- Power on ICM-3011 series and press space on Tera Term(within 3 seconds) to enter Freescale i.MX6 SOC Main Menu
- Select “8” to Enter Display Configuration
- Keep selecting “1” until the correct Primary Display has been selected
- Keep selecting “2” until the correct Primary Display Port has been selected
- Select “0” to Exit and Continue
- Select “S” to Save Settings
- Select “0” to Exit and Continue
- System will restart automatically and with correct display configuration